    "data_version": "4.0",
    "data_type": "CVE",
    "data_format": "MITRE",
    "CVE_data_meta": {
        "ID": "CVE-2023-2915",
        "ASSIGNER": "PSIRT@rockwellautomation.com",
        "STATE": "PUBLIC"
    },
    "description": {
        "description_data": [
            {
                "lang": "eng",
                "value": "The Rockwell Automation Thinmanager Thinserver is impacted by an improper input validation vulnerability, Due to improper input validation, a path traversal vulnerability exists when the ThinManager software processes a certain function. If exploited, an unauthenticated remote threat actor can delete arbitrary files with system privileges.   A malicious user could exploit this vulnerability by sending a specifically crafted synchronization protocol message resulting in a denial-of-service condition.  "
            }
        ]
    },
    "problemtype": {
        "problemtype_data": [
            {
                "description": [
                    {
                        "lang": "eng",
                        "value": "CWE-20 Improper Input Validation",
                        "cweId": "CWE-20"
                    }
                ]
            }
        ]
    },
    "affects": {
        "vendor": {
            "vendor_data": [
                {
                    "vendor_name": "Rockwell Automation",
                    "product": {
                        "product_data": [
                            {
                                "product_name": "ThinManager ThinServer",
                                "version": {
                                    "version_data": [
                                        {
                                            "version_affected": "=",
                                            "version_value": "11.0.0 - 11.2.6"
                                        },
                                        {
                                            "version_affected": "=",
                                            "version_value": "11.1.0 - 11.1.6"
                                        },
                                        {
                                            "version_affected": "=",
                                            "version_value": "11.2.0 - 11.2.7"
                                        },
                                        {
                                            "version_affected": "=",
                                            "version_value": "12.0.0 - 12.0.5"
                                        },
                                        {
                                            "version_affected": "=",
                                            "version_value": "12.1.0 - 12.1.6"
                                        },
                                        {
                                            "version_affected": "=",
                                            "version_value": "13.0.0 - 13.0.2"
                                        },
                                        {
                                            "version_affected": "=",
                                            "version_value": "13.1.0"
                                        }
                                    ]
                                }
                            }
                        ]
                    }
                }
            ]
        }
    },
    "references": {
        "reference_data": [
            {
                "url": "https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1140471",
                "refsource": "MISC",
                "name": "https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1140471"
            }
        ]
    },
    "generator": {
        "engine": "Vulnogram 0.1.0-dev"
    },
    "source": {
        "discovery": "UNKNOWN"
    },
    "solution": [
        {
            "lang": "en",
            "supportingMedia": [
                {
                    "base64": false,
                    "type": "text/html",
                    "value": "\n\n<ul><li>Update to the corrected software versions.</li><li>Limit remote access for TCP Port 2031 to known thin clients and ThinManager servers.</li></ul>"
                }
            ],
            "value": "\n  *  Update to the corrected software versions.\n  *  Limit remote access for TCP Port 2031 to known thin clients and ThinManager servers.\n\n\n"
        }
    ],
    "credits": [
        {
            "lang": "en",
            "value": "This vulnerability was reported to Rockwell Automation by Tenable Network Security."
        }
    ],
    "impact": {
        "cvss": [
            {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 7.5,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "NONE",
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
                "version": "3.1"
            }
        ]
    }
}