    "CVE_data_meta": {
        "ASSIGNER": "cert@cert.org",
        "DATE_PUBLIC": "2018-10-01T04:00:00.000Z",
        "ID": "CVE-2018-5402",
        "STATE": "PUBLIC",
        "TITLE": "The Auto-Maskin DCU 210E, RP-210E, and Marine Pro Observer Android App use an embedded webserver that uses unencrypted plaintext for the transmission of the administrator PIN"
    },
    "affects": {
        "vendor": {
            "vendor_data": [
                {
                    "product": {
                        "product_data": [
                            {
                                "product_name": "DCU-210E ",
                                "version": {
                                    "version_data": [
                                        {
                                            "affected": "<",
                                            "platform": "ARMv7",
                                            "version_name": "3.7",
                                            "version_value": "3.7"
                                        }
                                    ]
                                }
                            },
                            {
                                "product_name": "RP-210E",
                                "version": {
                                    "version_data": [
                                        {
                                            "affected": "<",
                                            "platform": "ARMv7",
                                            "version_name": "3.7",
                                            "version_value": "3.7"
                                        }
                                    ]
                                }
                            }
                        ]
                    },
                    "vendor_name": "Auto-Maskin"
                }
            ]
        }
    },
    "credit": [
        {
            "lang": "eng",
            "value": "Reporters: Brian Satira, Brian Olson, Organization: Project Gunsway"
        }
    ],
    "data_format": "MITRE",
    "data_type": "CVE",
    "data_version": "4.0",
    "description": {
        "description_data": [
            {
                "lang": "eng",
                "value": "The Auto-Maskin DCU 210E, RP-210E, and Marine Pro Observer Android App use an embedded webserver that uses unencrypted plaintext for the transmission of the administrator PIN Impact: An attacker once authenticated can change configurations, upload new configuration files, and upload executable code via file upload for firmware updates. Requires access to the network. Affected releases are Auto-Maskin DCU-210E, RP-210E, and the Marine Pro Observer Android App. Versions prior to 3.7 on ARMv7."
            }
        ]
    },
    "impact": {
        "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 9.1,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N",
            "version": "3.0"
        }
    },
    "problemtype": {
        "problemtype_data": [
            {
                "description": [
                    {
                        "lang": "eng",
                        "value": "CWE-319: Cleartext Transmission of Sensitive Information"
                    }
                ]
            }
        ]
    },
    "references": {
        "reference_data": [
            {
                "name": "VU#176301",
                "refsource": "CERT-VN",
                "url": "https://www.kb.cert.org/vuls/id/176301"
            },
            {
                "refsource": "MISC",
                "name": "https://www.us-cert.gov/ics/advisories/icsa-20-051-04",
                "url": "https://www.us-cert.gov/ics/advisories/icsa-20-051-04"
            }
        ]
    },
    "solution": [
        {
            "lang": "eng",
            "value": "The devices should implement TLS for authentication to administrator functions via embedded webserver.\n"
        }
    ],
    "source": {
        "discovery": "EXTERNAL"
    }
}