    "CVE_data_meta": {
        "ASSIGNER": "ics-cert@hq.dhs.gov",
        "DATE_PUBLIC": "2017-03-21T00:00:00",
        "ID": "CVE-2017-6015",
        "STATE": "PUBLIC"
    },
    "affects": {
        "vendor": {
            "vendor_data": [
                {
                    "product": {
                        "product_data": [
                            {
                                "product_name": "FactoryTalk Activation",
                                "version": {
                                    "version_data": [
                                        {
                                            "version_value": "FactoryTalk Activation Service, Version 4.00.02 and prior versions."
                                        }
                                    ]
                                }
                            }
                        ]
                    },
                    "vendor_name": "Rockwell Automation"
                }
            ]
        }
    },
    "data_format": "MITRE",
    "data_type": "CVE",
    "data_version": "4.0",
    "description": {
        "description_data": [
            {
                "lang": "eng",
                "value": "Without quotation marks, any whitespace in the file path for Rockwell Automation FactoryTalk Activation version 4.00.02 remains ambiguous, which may allow an attacker to link to or run a malicious executable. This may allow an authorized, but not privileged local user to execute arbitrary code with elevated privileges on the system. CVSS v3 base score: 8.8, CVSS vector string: (AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H). Rockwell Automation has released a new version of FactoryTalk Activation, Version 4.01, which addresses the identified vulnerability. Rockwell Automation recommends upgrading to the latest version of FactoryTalk Activation, Version 4.01 or later."
            }
        ]
    },
    "problemtype": {
        "problemtype_data": [
            {
                "description": [
                    {
                        "lang": "eng",
                        "value": "Unquoted search path or element CWE-428"
                    }
                ]
            }
        ]
    },
    "references": {
        "reference_data": [
            {
                "name": "96996",
                "refsource": "BID",
                "url": "http://www.securityfocus.com/bid/96996"
            },
            {
                "name": "https://rockwellautomation.custhelp.com/app/answers/detail/a_id/939382",
                "refsource": "MISC",
                "url": "https://rockwellautomation.custhelp.com/app/answers/detail/a_id/939382"
            },
            {
                "name": "https://ics-cert.us-cert.gov/advisories/ICSA-17-047-02",
                "refsource": "MISC",
                "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-047-02"
            }
        ]
    }
}