    "CVE_data_meta": {
        "ASSIGNER": "ics-cert@hq.dhs.gov",
        "ID": "CVE-2012-2515",
        "STATE": "PUBLIC"
    },
    "affects": {
        "vendor": {
            "vendor_data": [
                {
                    "product": {
                        "product_data": [
                            {
                                "product_name": "n/a",
                                "version": {
                                    "version_data": [
                                        {
                                            "version_value": "n/a"
                                        }
                                    ]
                                }
                            }
                        ]
                    },
                    "vendor_name": "n/a"
                }
            ]
        }
    },
    "data_format": "MITRE",
    "data_type": "CVE",
    "data_version": "4.0",
    "description": {
        "description_data": [
            {
                "lang": "eng",
                "value": "Multiple stack-based buffer overflows in the KeyHelp.KeyCtrl.1 ActiveX control in KeyHelp.ocx 1.2.312 in KeyWorks KeyHelp Module (aka the HTML Help component), as used in EMC Documentum ApplicationXtender Desktop 5.4; EMC Captiva Quickscan Pro 4.6 SP1; GE Intelligent Platforms Proficy Historian 3.1, 3.5, 4.0, and 4.5; GE Intelligent Platforms Proficy HMI/SCADA iFIX 5.0 and 5.1; GE Intelligent Platforms Proficy Pulse 1.0; GE Intelligent Platforms Proficy Batch Execution 5.6; GE Intelligent Platforms SI7 I/O Driver 7.20 through 7.42; and other products, allow remote attackers to execute arbitrary code via a long string in the second argument to the (1) JumpMappedID or (2) JumpURL method."
            }
        ]
    },
    "problemtype": {
        "problemtype_data": [
            {
                "description": [
                    {
                        "lang": "eng",
                        "value": "n/a"
                    }
                ]
            }
        ]
    },
    "references": {
        "reference_data": [
            {
                "name": "ADV-2009-2795",
                "refsource": "VUPEN",
                "url": "http://www.vupen.com/english/advisories/2009/2795"
            },
            {
                "name": "ADV-2009-2793",
                "refsource": "VUPEN",
                "url": "http://www.vupen.com/english/advisories/2009/2793"
            },
            {
                "name": "36546",
                "refsource": "BID",
                "url": "http://www.securityfocus.com/bid/36546"
            },
            {
                "name": "http://support.ge-ip.com/support/resources/sites/GE_FANUC_SUPPORT/content/live/KB/14000/KB14863/en_US/GEIP12-04%20Security%20Advisory%20-%20Proficy%20HTML%20Help.pdf",
                "refsource": "CONFIRM",
                "url": "http://support.ge-ip.com/support/resources/sites/GE_FANUC_SUPPORT/content/live/KB/14000/KB14863/en_US/GEIP12-04%20Security%20Advisory%20-%20Proficy%20HTML%20Help.pdf"
            },
            {
                "name": "36914",
                "refsource": "SECUNIA",
                "url": "http://secunia.com/advisories/36914"
            },
            {
                "name": "36905",
                "refsource": "SECUNIA",
                "url": "http://secunia.com/advisories/36905"
            },
            {
                "name": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-131-02.pdf",
                "refsource": "MISC",
                "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-131-02.pdf"
            },
            {
                "name": "http://retrogod.altervista.org/9sg_emc_keyhelp.html",
                "refsource": "MISC",
                "url": "http://retrogod.altervista.org/9sg_emc_keyhelp.html"
            }
        ]
    }
}